Skip to content
Sydney, Australia, 2024

Shade roof with Webnet for a car park

At a commuter car park in Western Sydney Webnet stainless steel mesh creates a vine-covered shade roof. Independent monitoring by Western Sydney University recorded surface temperatures up to 35 degrees lower beneath the green canopy.

Initial situation and concept

Open-air car parks are among the hottest surfaces in a city. Asphalt, concrete and parked cars absorb heat during the day and release it well into the evening. Trees are the usual answer, but they take 20 years or more to provide useful shade.

The shade roof (Cool Roof System) offers a faster alternative. Developed by our partner Tensile Design & Construct together with Cumberland City Council and Western Sydney University, it is a modular, freestanding steel structure carrying a tensioned Webnet roof, across which fast-growing native vines are trained to form a living canopy. Following a first prototype at Holroyd Gardens in 2023, the second-generation system was installed in 2024 at the commuter car park beside Wentworthville train station (with funding from the Office of the NSW Chief Scientist & Engineer).

Construction and implementation

Three freestanding steel frames support a roof over eight parking bays, covering 138 square meters. The structure was engineered around the existing bay layout, so not a single parking space was lost. Building on the lessons from the prototype, the roof was lowered at the back and tilted 7 degrees upwards towards the front – shortening the climb for the vines and encouraging them to keep spreading across the mesh. Circular hollow steel sections with tapered ends give the structure a lighter appearance, and a ceramic Super Therm® coating reflects solar radiation to stop the steel from heating up.

The stainless steel Webnet mesh is tensioned with ropes and tension bolts to form the roof. Stainless steel trellis ropes guide Wonga Wonga vines (Pandorea pandorana) and Bower vines (Pandorea jasminoides) from the ground up to the mesh, supported by an irrigation system. Within 22 months of planting, the vines had covered 71 percent of the roof.

Monitoring by Western Sydney University showed that surface temperatures under the canopy were on average 19 degrees and up to 35 degrees lower than in the open car park. “Feels-like” (black globe) temperatures dropped by up to 10 degrees, and the canopy blocked on average 74 percent of UV radiation and around 60 percent of near-infrared radiation – with the cooling effect strongest on the hottest days. The project received the ShadeSmart Award at the 2026 AILA NSW Landscape Architecture Awards, and the system can be adapted to council and commuter car parks, schools, shopping centres and hospital campuses.

 

Technical details

Application
Cool Roof System: Webnet as a trellis structure for a shade roof in an open-air car park

Dimensions
Roof area: 138 m² (width 20 m, depth 6.9 m), covering eight parking spaces
Height: 2.14 m at the rear, rising to 2.77 m at the front; 7-degree roof pitch

Products
Webnet (rope diameter 1.5 mm, mesh aperture 180 mm)

Lacing rope (diameter 6 mm, 6 × 7 + WC) with turnbuckle and clevis round swaged, M6

Services
Design, engineering, fabrication and installation of the steel structure and Webnet roof, planting and maintenance, support for the scientific monitoring

Implementation
2024

Project partners
Client: Cumberland City Council
Design, fabrication and installation: Tensile Design & Construct
Thermal coating: NEOtech Coatings Australia (Super Therm®)
Scientific monitoring: Western Sydney University

Photos
Guy Wilkinson